B-12, VISHRANTIKA APPARTMENT, PLOT NO. 5A, SECTOR-3, DWARKA, NEW DELHI-110075
9315439912 (Number Shared by Promoter in Public)
hlresidency@gmail.com
AAO0860
AALFH9487P
HL RESIDENCY INDUSTRIAL
GUBHANA
BADLI
JHAJJAR
01276297888
8813888101 (Number Shared by Promoter in Public)
hlresidency@gmail.com
AJAY
01276297888
8813888101 (Number Shared by Promoter in Public)
hlresidency@gmail.com
As per sub-rule(2) of rule 3 of the Haryana Real Estate (Regulation and Development) Rules,2017, the fee for registration of the project as has been calculated as follows:
2. The aforesaid fees is hereby deposited vide following Drafts/ Banker’s Cheques:-
Sr No.
Draft/Cheque No.
Draft Date
Amount
Payee Bank
Payable To
1
188477
12-05-2023
200000
STATE BANK OF INDIA
HRERA Panchkula
16.03125 (Acre)
NA
1
15.30908 (Acre)
LICENSE NO. 103 OF 2023 DATED 10.05.2023 GRANTED BY TOWN AND COUNTRY PLANNING HARYANA
Yes
2900 Lakhs
800 Lakhs
0 Lakhs
1600 Lakhs
500 Lakhs
Sr. No.
Land area under usage
Area of land (Acres)
1
PLOTS TO BE SOLD
9.15
2
LAND AREA TO BE USED FOR CONSTRUCTION OF APARTMENTS
0
3
CONSTRUCTION OF ROADS
5.384699
4
PAVEMENTS
0
5
PARKS AND PLAYGROUNDS
0
6
GREEN BELTS
0
7
VEHICLE PARKINGS
0
8
ELECTRICITY SUB-STATION
0
9
CLUB HOUSE
0
10
SEWAGE AND SOLID WASTE TREATMENT FACILITY
0
11
AREA TO BE LEFT FOR TRANSFERRING TO THE GOVERNMENT FOR COMMUNITY SERVICES
0
12
ANY OTHER
0
13
COMMERCIAL
0.765221
Total
15.29992
Facility
External/ connecting service to be provided by (Name the agency)
Whether Approval taken from the agency concerned. Yes/No (Annex details in folder C)
ROADS
HL RESIDENCY AND DEVELOPERS LLP
No
WATER SUPPLY
HDRA/HL RESIDENCY AND DEVELOPERS LLP
No
ELECTRICITY
UHBVN
No
SEWAGE DISPOSAL
HDRA/HL RESIDENCY AND DEVELOPERS LLP
No
STORM WATER DRAINAGE
HL RESIDENCY AND DEVELOPERS LLP
No
Sr. No.
Name of the facility
Estimated cost (In Lakhs)(Within the project area only)
Remarks: Yet to be prepared / Submitted to HUDA, Town & Country Planning Department/ as per project report etc. (Annex relevant documents showing costing details etc. in folder C)
1
INTERNAL ROADS AND PAVEMENTS
510
YET TO BE PREPARED
2
WATER SUPPLY SYSTEM
134
YET TO BE PREPARED
3
STORM WATER DRAINAGE
42
YET TO BE PREPARED
4
ELECTRICITY SUPPLY SYSTEM
215
YET TO BE PREPARED
5
SEWAGE TREATMENT & GARBAGE DISPOSAL
116
YET TO BE PREPARED
6
STREET LIGHTING
95
YET TO BE PREPARED
7
SECURITY AND FIRE FIGHTING
400
YET TO BE PREPARED
8
PLAYGROUNDS AND PARKS
0
YET TO BE PREPARED
9
CLUB HOUSE/COMMUNITY CENTRE
0
YET TO BE PREPARED
10
SHOPPING AREA
0
YET TO BE PREPARED
11
RENEWABLE ENERGY SYSTEM
0
YET TO BE PREPARED
12
SCHOOL
0
YET TO BE PREPARED
13
HOSPITAL/DISPENSARY
0
YET TO BE PREPARED
14
ANY OTHER
88
YET TO BE PREPARED
10-05-2023 (date)
10-05-2023 (date)
01-07-2023
09-05-2028
Plot Area(In Square Meter)
Number of plots in the project
1275.102
5
1135.276
6
1467.2768
1
368.82
7
369.04
49
447.60
1
367.53
1
310.5075
3
Type
Carpet area(In Square Meter)
Number of apartments
Number of towers
Apartment/Shops/Other Buildings
0
0
0
Expenditure incurred till the date of application (In Lakhs)
Particulars
Expenditure
Apartments
0
Shops
0
Plots
0
Expenditure to be made in each quarter (In Lakhs)
Particulars
Expenditure to be made in each quarter ()
Apr-June
July-Sep
Oct-Dec
Jan-Mar
Expenditure incurred till the date of application (In Lakhs)
Particulars
Expenditure
Roads & Pavements
0
Water Supply System
0
Sewerage treatment & garbage disposal
0
Electricity Supply System
0
Storm Water Drainage
0
Parks and Playgrounds
0
Clubhouse/community centres
0
Shopping area
0
Other
0
Expenditure to be made in each quarter (In Lakhs)
Particulars
Expenditure to be made in each quarter ()
Apr-June
July-Sep
Oct-Dec
Jan-Mar
No
No
ICICI BANK
046105500757
ICIC0000461
110229064
000461
SAVITA DALAL
ATTACHED
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Statutory Approvals
Statutory Approvals Status
Date
I. LICENSE NO 103 OF 2023
ALREADY BEEN OBTAINED
10-05-2023
II. LAYOUT PLAN NO. DGTCP 9222 DATED 10.05.2023
ALREADY BEEN OBTAINED
10-05-2023
No
No
NOT APPLICABLE
SPECIFICATION OF CONSTRUCTION
Specification of apartments and other buildings including the following:
1
FLOORING DETAILS OF VARIOUS PARTS OF HOUSE
NOT APPLICABLE
2
WALL FINISHING DETAILS
NOT APPLICABLE
3
KITCHEN DETAILS
NOT APPLICABLE
4
BATHROOM FITTINGS
NOT APPLICABLE
5
WOOD WORK ETC
NOT APPLICABLE
6
DOORS AND WINDOS FRAMES
NOT APPLICABLE
7
GLASS WORK
NOT APPLICABLE
8
ELECTRIC FITTINGS
NOT APPLICABLE
9
CONDUCTING AND WIRING DETAILS
NOT APPLICABLE
10
CUPBOARD DETAILS
NOT APPLICABLE
11
WATER STORAGE
NOT APPLICABLE
12
LIFT DETAILS
NOT APPLICABLE
13
EXTERNAL GLAZINGS
NOT APPLICABLE
13.1
WINDOWS/GLAZINGS
NOT APPLICABLE
14
DOORS
NOT APPLICABLE
14.1
MAIN DOORS
NOT APPLICABLE
14.2
INTERNAL DOORS
NOT APPLICABLE
15
AIR CONDITIONING
NOT APPLICABLE
16
ELECTRICAL FITTINGS
NOT APPLICABLE
17
CNG PIPE LINE
NOT APPLICABLE
18
PROVISION OF WIFI AND BROADBAND FACILITY
NOT APPLICABLE
19
EXTERNAL FINISHING/COLOUR SCHEME
NOT APPLICABLE
20
INTERNAL FINISHING
NOT APPLICABLE
SPECIFICATION UNIT WISE
1 . LIVING/DINING/FOYER/FAMILY LOUNGE
1 . 1
FLOOR
NOT APPLICABLE
1 . 2
WALLS
NOT APPLICABLE
1 . 3
CEILING
NOT APPLICABLE
2 . MASTER BEDROOM/DRESSROOM
2 . 1
FLOOR
NOT APPLICABLE
2 . 2
WALLS
NOT APPLICABLE
2 . 3
CEILING
NOT APPLICABLE
2 . 4
MODULAR WARDROBES
NOT APPLICABLE
3 . MASTER TOILET
3 . 1
FLOOR
NOT APPLICABLE
3 . 2
WALLS
NOT APPLICABLE
3 . 3
CEILING
NOT APPLICABLE
3 . 4
COUNTERS
NOT APPLICABLE
3 . 5
SANITARY WARE/CP FITTINGS
NOT APPLICABLE
3 . 6
FITTING/FIXTURES
NOT APPLICABLE
4 . BED ROOMS
4 . 1
FLOOR
NOT APPLICABLE
4 . 2
WALLS
NOT APPLICABLE
4 . 3
CEILING
NOT APPLICABLE
4 . 4
WARDROBES
NOT APPLICABLE
5 . TOILET
5 . 1
FLOOR
NOT APPLICABLE
5 . 2
WALLS
NOT APPLICABLE
5 . 3
CEILING
NOT APPLICABLE
5 . 4
COUNTERS
NOT APPLICABLE
5 . 5
SANITARY WARE/CP FITTINGS
NOT APPLICABLE
5 . 6
FIXTURES
NOT APPLICABLE
6 . KITCHEN
6 . 1
FLOOR
NOT APPLICABLE
6 . 2
WALLS
NOT APPLICABLE
6 . 3
CEILING
NOT APPLICABLE
6 . 4
COUNTERS
NOT APPLICABLE
6 . 5
FIXTURES
NOT APPLICABLE
6 . 6
KITCHEN APPLIANCES
NOT APPLICABLE
7 . UTILITY ROOMS/UTILITY BALCONY/TOILET
7 . 1
FLOOR
NOT APPLICABLE
7 . 2
WALLS & CEILING
NOT APPLICABLE
7 . 3
TOILET
NOT APPLICABLE
7 . 4
BALCONY
NOT APPLICABLE
8 . SIT-OUTS
8 . 1
FLOOR
NOT APPLICABLE
8 . 2
WALLS & CEILING
NOT APPLICABLE
8 . 3
RAILINGS
NOT APPLICABLE
8 . 4
FIXTURES
NOT APPLICABLE
Sr. No.
Document Description
Date of Document Upload
View Document
1
A COMPLETE SET OF THE LAST APPROVED BUILDING PLANS
CERTIFICATE FROM A CHARTERED ACCOUNTANT CERTIFYING THAT THE INFORMSTION PROVIDED BY THE APPLICANT IN FORM REP-1-C-X IS CORRECT AS PER THE BOOKS OF ACCOUNTS/ BALANCE SHEET OF THE APPLICANT